Product Introduction:
hlc-1x series definite purpose contactors is provided by ZHEJIANG HONGLI ELECTRIC CO.,LTD,a major Educational Toys supplier in Toy, Game & Hobby wholesale industry in China.You can check out the specification of hlc-1x series definite purpose contactors below or get any optional result clicking into the following keywords and you can check the authentications and testimonials of hlc-1x series definite purpose contactors .
Description:
specifications:
1) name: 1 pole definite purpose contactor
2) model number: hlc-1x
3) contact:
a) arrangements: 1 pole x with shunt
b) structure: double make contacts
c) materials: silver cadmium oxide (10% 30amp, 13% 40amp)
d) max. loading rating: see contact rating chart
4) coil:
a) coil voltage: 50 / 60hz (see coil rating chart)
b) nominal resistance: see coil rating chart
c) nominal inrush power: 5va 60hz, 6va 50hz
d) coil temperature rise: 65oc (max.)
e) class of insulation: 130oc class b
5) operation:
a) must operate voltage: 85% of nominal coil voltage or less
(24v ac=75% or less)
b) must release voltage: 10% - 60% of operating voltage
c) initial operating time: 20ms typical
d) initial release time: 10ms typical
e) bounce time: 0 to 10 ms typical
6) environment:
a) temperature range (storage and operation): -40 ~ 65oc
7) initial dielectric strength:
a) between contacts and coil: 2,500v ac
b) between poles: 2,500v ac
c) between open contacts: 2,500v ac
8) mechanical data (power pole termination: wire size, tightening torque):
a) #10-32 screw: 16 - 8 awg, 22ibf. -in.(2.49nm)
b) box lug: 14 - 4 awg, 40ibf. -in. (4.52 nm)
9) coil termination: dual 0.250 quick connects (6.35mm)
10) unit weight without optional cover: 7oz. (200g)
11) life expectancy: depends upon duty cycle, load and environmental
conditionals
12) mechanical life:
a) design requirement ar1780 = 500,000 operations
b) minimum test requirement = 1,000,000 operations at 60 operations
per minute, 50% duty cycle, 150f and 110% of nominal coil voltage
13) electrical life test results:
a) 40 and 50 rla (resistive load)
b) 250,000 operations make, carry and break 100% pf. 600v ac 30 fla rated
c) 200,000 operations make lra 40 - 50% pf., break 125% fla 75 to 80%
pf. 240v ac
d) 250,000 operations make, carry, break 75 - 80% pf. 240v ac
e) 250,000 operations make, carry, break 75 -o 80% pf. 600v ac
40 fla rated
f) 100,000 operations make lra 40 - 50% pf., break 125% fla 75 - 80%
pf. 240v ac
g) 250,000 operations make, carry, break 75 - 80%pf. 240v ac
h) 300,000 operations make, carry, break 75 - 80%pf. 600v ac