Product Introduction:
patient monitor is provided by Shenzhen Comen Medical Instruments Co., Ltd.,a major Glass Furniture supplier in Furniture & Furnishing wholesale industry in China.You can check out the specification of patient monitor below or get any optional result clicking into the following keywords and you can check the authentications and testimonials of patient monitor .
Description:
12.1 Color TFT Display with Maximum 7 Waveforms
Optional Multi-language Operation Menu
Support Patient Information Input
12-lead ECG Waveforms Display
Up to 10 Minutes ECG Replay Capacity
Analysis for Pace-making , Arrhythmia and S-T segment
Two Optional Display Method: Refreshing and Rolling
Various Waveforms can be Flexibly Grouped and Changed in Color
Power Fail Safeground Function, Capable of Storing Previous Monitoring Data
Digital SpO2 Technique, Precise Measurement for Low Perfusion and Finger Shaking
Protection Against Interference from Defibrillation and High-frequency Electrotome
Intellectualized Voice/Light Alarms Accurately Transmit Diseases
Adult/Pediatric/Neonatal measurement modes
Compatible with Central Monitoring System, Support Wireless Connection
Technical Parameter
HR
Measure range: 0-250bpm
Accuracy:�2bpm
Alarm Range: upper limit: 40-250bpm
Lower limit: 20-160bpm
Respiration
Measure range: 0-100%
Resolution: 1%
Measure accuracy: �1%
SpO2
Measurement range: 0-100%
Resolution: 1%
Accuracy: (70-100%) �2% Adult
�3% Neonatal
0-69% unspecified
Alarm range: 0-100%
Pulse
Measure Range: 0-250bpm
Accuracy: �2bpm or 2%
Resolution: 1bpm
Alarm range: 0-254bpm
Temperature
Range: 25℃-45℃
Accuracy: �0.1℃ (32℃-42℃)
Resolution 0.1℃
ECG
Input: 10-lead
Lead Selection: 12-lead Automatic Shift
Scan Speed: 25mm/s 50mm/s
Gain Selection: �0.5, �1, �2, �4
NIBP
Measure Mode: Automatic
Work Mode: Manual/Automatic/Continuous Oscillometric
Range: Adult/Pediatric/Neonatal
Protection: Double Security Protection
Measurement types: Systolic, Diastolic, Mean
Measurement range: Adult: 10-270mmHg
Pediatric: 10-200mmHg
Neonatal: 10-135mmHg
Over-pressure protection: yes
Resolution: 1mmHg
Alarm: Systolic, Diastolic, Mean
IBP
Channel: double
Pressure Sensor: Sensitivity: 5V/V/mmHg
Pressure Name: ART, PA, CVP, RAR, LAP, ICP
Alarm: Yes
Measurement unit: mmHg/kPa selectable
Resolution: 1mmHg
Accuracy: �1mmHg or 2%, whichever is greater
CO2
Measure Mode: Bypass Mode
Measure Parameter: CO2 Breathe-out, Minimum CO2 Inbreathe, Airway HR
Alarm: Yes
Alarm
Range: Adjustable from Lower to Upper Limit
Cause: Irregular Indication
Indications: Audible and Visual Dual Indications
Printer (Optional)
Type: 50mm Thermal Printer
Port: Standard Parallel
Printing Setting: Manual, Alarm Triggered, Timing Triggered, Live Record
Recorder speed: 25mm/s, 50mm/s
Safety
In Compliance with IEC60601 and GB9706 Related Standards
Weight
6kg
Dimension
320mm(W)�280mm(H)�170mm(D)
Power Requirement
Voltage: AC100-240V 50HZ/60HZ
Carton